What should school alarms have: horns and strobes or audio messages?

Most state fire, building, and life safety codes require all new K-12 schools to have a fire alarm system which includes horns and strobes. For schools with more than 100 occupants, it is required by NFPA that the systems initiate an audio alarm to notify occupants. This alarm must meet requirements of, and is installed in accordance with, NFPA 72®, National Fire Alarm and Signaling Code.

A fire alarm system has at least horns and strobes that signal when the system is activated. The horns and strobes are the traditional alert and are required for all fire alarm systems. Adding audio messages to your fire alarm takes your system to the next level. Audio messages can be individualized for specific circumstances, instead of a generic horn and strobe, and provide more information for how to respond to the situation.

NFPA 72 permits the emergency voice/alarm communications system to provide other uses, such as for public address (PA) or mass notification purposes. Some features of the PA system may seem to interfere with an emergency communication system such as the ability to lower the volume on speakers, emergency notification systems can override the local volume controls to reset them to the emergency sound level. In addition, emergency notification systems need to be set to override any PA non-emergency messages. Specific design requirements for a school’s emergency communication system also include the ability to broadcast live voice messages by paging zones, and requires an emergency power supply which can support the system for 24 hours.

NFPA 72, Chapter 24, provides guidance for messages recorded in the emergency communication system. It requires that messages be developed to address each scenario outlined in the school’s emergency response plan (which means schools are required to have an emergency response plan). Emergency messages must have content that provides information and instructions to the building occupants. An evacuation message must use the standard alarm evacuation signal consisting of a Temporal-3 alarm signal (which is the recommended standard evacuation pattern for smoke and fire alarms) for at least two cycles before and after the recorded voice message.

While this overview was a general review of requirements for school emergency notification systems, it is important to review your state and local code requirements as they may dictate other design requirements. You should also review your emergency response plan with your local police and fire department to get their input and coordinate responses.